  1. Burning rate: 250 Kg/hr.
  2. It should be able to Operate not Less than 10 hours/day
  3. This incinerator must be able to destruct all combustible wastes produced by hospitals, private clinics, laboratories, institutes, etc…
  4. Design Specification: Types A, B, C, D, and E of medical waste
  5. “PYROLYTIC” combustion, by controlling the gasification of waste.
  6. The incinerator must avoid the release of black smoke and fine dust, (Smokeless) during the loadings.
  7. It should be able to reduce the volume of wastes by 98%.
  8. It should be able to hold emission in the second burn with gas residence of not less than 2 seconds.

The incineration should be completely free from visible smoke as well as offensive odours.

  1. The lower calorific power (L.C.P) of this waste will be 3,500 kcal/kg
  • The Temperatures of combustion:Minimum will be 850oC and max 1400oC
  • Post combustion: >1100o
  1. The Internal diameter of the Chimney: Ø 400mm² and its height: 8 Meter
  2. The Volume of the combustion chamber: Not Less Than 2.3 M³
  3. Burner operation should be Automatic On/Off
  4. Fuel : diesel, LPG, Natural Gas, Bio fuel
  5. The supplier must provide  necessary information for the best of  the installation

This incinerator with “PYROLYTIC” combustion must have:

  1. A combustion chamber of waste:

* Perfectly tight door for the manual loading of waste.The loading should be Manual, Batch Load,

* A burner of lighting which the use is limited to the ignition of waste.

* Top Loading loading with door seals gone up on hinges, wheel of screw plug, flexible joint, and stuffing insulating out of refractory.

* The insulation of the combustion chamber should be composed of refractory bricks, having a high content of aluminum and insulates bricks in order to assure a minimum temperature on   the outside sheet metal.

* Composition of the refractory;

  • Refractory concrete :
    • . Thickness : ≥100 mm
    • . Nature: 42% of Al203
  • Insulate in fibrous panels :
    • . Thickness: ≥75 mm
  • Nature: Calcium silicate.

* Burner of lighting of waste, with fuel, standard mono-bloc casting guiding plunging flame, lighting and safety of electronic ignition, permanent ventilation, electromagnetic sluice gate of regulation and isolating valve.

* Plate of combustion in Carborundum, avoiding the fixing of glass and slags.

  1. Load Method: Top Loading

 

  1. A chamber of post combustion of gases

* A burner of combustion of gases,

* A device of injection of air allowing a total recombustion of gases,

* A device of air inlet of cooling of waste gases,

* A sheath of evacuation of the gases burnt.

* Carcass in strong sheet steel with support of connection.

* Composition of the refractory;

  • Refractory concrete :
    • Thickness : ≥180 mm
    • Nature: 65% of Al203
  • Insulate in fibrous panel :

Recent Posts

  • Incinerador con depurador húmedo tipo 1 o 3 áreas
  • Incineradores móviles de residuos en contenedores HICLOVER CA-200
  • Crematorio para perros HICLOVER A600
  • Terapia de incineración de desechos PRECIO DE QUEMA: 100-150 kg por hora HICLOVER TS150
  • HICLOVER Quemador móvil pequeño Con Rueda así como Freno
  • Cremación para perros de gran capacidad HICLOVER Versión A1500 con automóvil E-Power. Puerta
  • Planta de quemadores con controlador PLC automático con calentadores de calor duales y también HICLOVER YD-30C de doble cámara con depurador húmedo
  • Incinerador de desechos médicos HICLOVER TS10 PLC 10 kg por hora
  • Incineración de residuos HICLOVER Modelo TS75
  • incinerador de desechos médicos
  • Incinerador móvil de desechos médicos de rango pequeño con carro o rueda
  • 30kgs tasa 60kgs aceite de alimentación y también quemador de residuos minúsculo
  • Quemador tipo contenedor premontado
  • Pequeño quemador de residuos, capacidad de 10 kg por hora, control PLC Modelo TS10 (PLC).
  • Incineradores de residuos clínicos de 30 kg para residuos covid19
©2026 HICLOVER Incinerator | WordPress Theme by Superbthemes.com