Tool Dimension : Burning Price : 60-80 kg/hr Pyrolytic Double Chamber Burner

Posted on April 24, 2022

Items/Model

TS100( PLC)

Picture

Concept

Waste Incineration Treatment

Burn Rate

60-80 kg/hour

Control Putting

PLC( Programmable Reasoning Controller Burner)

Burning Chamber

1200L

Internal Dimensions

120x100x100cm

Additional Chamber

600L

Smoke Filter Chamber

Yes( Dry Scrubber)

Feed Mode

Guidebook

Voltage

220V

Oil Utilization (kg/hour)

Typical 20.4

Gas Utilization (m3/hour)

***

Temperature Monitor

Digital Present

Temperature Security

Yes

Oil Storage Tank

1100L

Feed Door

80x60cm

Smokeshaft

10Meter

Chimney Kind

Stainless Steel

1st. Chamber Temperature Level

800 ℃–– -1000 ℃

2nd. Chamber Temperature Level

1000 ℃ -1200 ℃

Residency Time

2.0 Sec.

Gross Weight

6000kg

Exterior Dimensions

260x150x180cm


The requirement is for a pyrolytic double-chamber incinerator. The incinerator shall be capable of using diesel 
fuel as a supplemental fuel oil.
It should incorporate an Air Pollution Control (APC) System suitable for basic emission control.
The proposed incinerators shall be appropriate for critical harsh environmental conditions, suitable for rapid 
deployment, and different climate zones (e.g. desert, tropical country, mountain, etc.) in which there are several 
variations of the relative natural forces (e.g. temperature, humidity, wind, etc.) for a minimum period of 10 years 
if the specified maintenance schedule is followed.
The incinerators should be supplied assembled, whenever possible, and all parts and components should be 
packaged on pallets in order to be transported via road, air (via helicopters or air-cargoes, e.g. MI8 or C130) 
and via sea in a 20’ ISO sea shipping containers.

HICLOVER – Medical Environmental 


 
WWW.HICLOVER.COM
Waste Incinerators
Medical Waste Incinerator
Pet Animal Cremation
Solid Waste Incinerator

Tel:  +86-25-8461 0201   
Mobile: +86-13813931455(whatsapp/wechat)
Website: www.hiclover.com  
Email: [email protected]
Email: [email protected]  
Nanjing Clover Medical Technology Co.,Ltd.

 

dav
dav

2020-03-21

(adsbygoogle = window.adsbygoogle || []).push({});

Recent Posts

  • incineradores en 3 instalaciones para refinar los desechos de atención médica
  • arrojar desechos peligrosos y también incineradores de chimeneas
  • Sistema de incinerador
  • Quemadores
  • INCINERADORES LOCALES DE RESIDUOS FUERTES
  • especificación de la planta incineradora
  • Incineradores de desechos médicos
  • PROPUESTA de incinerador de desechos médicos
  • Directiva de emisiones 2000/76 / EC
  • INCINERADOR DE RESIDUOS
  • los tres incineradores para quemar y para incinerar medicamentos y compuestos nocivos
  • un incinerador de animales para la cremación de perros
  • Calentador de incineración para quemar patalogical
  • Componentes del cuerpo animal, otros desechos biomédicos, excrementos de órganos corporales
  • Incinerador capaz de manejar entre 300 y 500 kg equipado con el sistema de lavado húmedo
©2026 HICLOVER Incinerator | WordPress Theme by Superbthemes.com