Skip to content
Menu
  • Home
  • RFQ
  • Shop
  • Contact
HICLOVER Incinerator

Mobile Diesel Fired Incinerator in container

Posted on June 25, 2021
Mobile Diesel Fired  Incinerator in container, 
supplied with the following specifications:
complete with constant ventilation fans for extraction, 
factory installed inside one 20ft ISO container complete with lighting, ventilation fan, fire security, 3 access doors, and a 1200 litre fuel tank complete with a piping. 
Fully containerised mobile  waste management solution for medical, animal, and industrial waste applications.
Installed in Container (ISO) : 20”
or its nearest equivalent model “
Tender Technical Specification
Destruction rate of 50kg/hr
Hot Hearth Principle
Refractory insulation:
a. Silicon carbide floor
b. Minimum 22mm insulation thickness
c. Brick lined Refractory insulation
d. Three layers of refractory insulation
e. Temperature Rating 1650 deg.C
f. 42% alumina fire bricks
Primary Chamber:
a. 120Kw Burner 
b. Dedicated independent fan system, damper controlled. 
c. Thermostatic Sensor 
d. Dimensions – 700mm x 700mm x g00mm
e. Square Chamber with curved floor for liquid centralization
Hot Hearth Chamber:
a. 120Kw Burner
b. Thermostatic Sensor 
c. Minimum Temperature of 1100 deg.C as per WHO guidelines. 
d. Two second retention time – Proven with CFD modeling.
Steel Construction:
a. constructed from 8mm & 1Omm steer plate 
b. Painted two pack paint system, red with black flashing
Control Panels:
a. Door dimensions 700mm x 700mm
b. Front mounted ash collection box.
Control Panels:
a. AiController
b. Plug and play 
c. Threezone monitoring of:
i)Primary chamber
              ii) Secondary chamber
              iii) Hot hearth
d. Digital display
e. Burner on-off indication lights 
f. Timer
Chimney:
a. Mild steel painted red
b. Refractory insulated with 50mm of insulation.
Unit Dimensions:
1840mm x 1 ‘1 50mm x 1950mm high.
Safety:
a. Burner door cut-off switches
b. Fire valve fitted to fuel system 
c. Maximum noise at 1m x g0 decibels 
d. Exterior temperature 70 deg.C Max

Recent Posts

  • INCINERADOR PIROLÍTICO de residuos clínicos
  • incineradores en 3 instalaciones para refinar los desechos de atención médica
  • arrojar desechos peligrosos y también incineradores de chimeneas
  • Sistema de incinerador
  • Quemadores
  • INCINERADORES LOCALES DE RESIDUOS FUERTES
  • especificación de la planta incineradora
  • Incineradores de desechos médicos
  • PROPUESTA de incinerador de desechos médicos
  • Directiva de emisiones 2000/76 / EC
  • INCINERADOR DE RESIDUOS
  • los tres incineradores para quemar y para incinerar medicamentos y compuestos nocivos
  • un incinerador de animales para la cremación de perros
  • Calentador de incineración para quemar patalogical
  • Componentes del cuerpo animal, otros desechos biomédicos, excrementos de órganos corporales
©2026 HICLOVER Incinerator | WordPress Theme by Superbthemes.com