    minimum technical requirements   Item 1 Incinerator model A  

Posted on June 30, 2021

 

 

minimum technical requirements

 

Item 1

Incinerator model A

 

Burn Rate 65kg/h minimum

 

Weight (kg), please indicate:

 

Secondary Chamber

 

Gas Retention Time – 2 Seconds

 

Fuel – Diesel/LPG/LNG, please indicate

 

Power Supply for Control Box – 220V-240V 50Hz single phase

 

Minimum operating temperature 850 °C, please indicate

 

One year Spare Parts Package for complete maintainability

Item 2

10m Hose Pipe, indicate length

Item 3

I000 Litre Fuel Tank + Pipe System, indicate volume

Item 4

Additional chimney extension, indicate height

 

Warranty, indicate no of years

 

 

 

 

minimum technical requirements

Incinerator model B

Burn Rate 150kg/h minimum

Weight (kg), please indicate:

Secondary Chamber

Gas Retention Time – 2 Seconds

Diesel/LPG/LNG, please indicate

Power Supply for Control Box- 220V-240V 50Hz single phase

Minimum operating temperature 920 °C, please indicate

One year Spare Parts Package for complete maintainability

10m Hose Pipe, indicate length

I000 Litre Fuel Tank + Pipe System, indicate volume

Additional chimney extension, indicate height

Warranty, indicate no of years

 

 

 

minimum technical requirements

Incinerator model C

Burn Rate 250kg/h minimum

Weight (kg) please indicate:

Secondary Chamber

Gas Retention Time 2 Seconds

Fuel Diesel/LPG/LNG, please indicate

Power Supply for Control Box 220V-240V 50Hz single phase

Minimum operating temperature 920 °C, please indicate

One year Spare Parts Package for complete maintainability

10m Hose Pipe, indicate length

I000 Litre Fuel Tank + Pipe System, indicate volume

Additional chimney extension, indicate height

Warranty, indicate no of years

 

 

minimum technical requirements

High Temperature Waste Incinerator

HTW Incinerator model D

Burn Rate – 150kg/hour minimum

Weight (kg), please indicate:

Secondary Chamber

Gas Retention Time 2 Seconds

Fuel Diesel/LPG/LNG, please indicate

Power Supply for Control Box 220V-240V, single phase 50-60Hz

Minimum operating temperature 1200°C, please indicate

One year Spare Parts Package for complete maintainability

10m Hose Pipe, indicate length

1000 Litre Fuel Tank + Pipe System, indicate volume

Additional chimney extension, indicate height

Warranty, indicate no of years

 

 

 

MOBILE INCINERATORS

 

minimum technical requirements

 Mobile Incinerator

Item 17

Mobile Incinerator model E

 

Burn Rate 50kg/h minimum

 

Weight (kg), please indicate:

 

Secondary Chamber

 

Gas Retention Time – 2 Seconds

 

Fuel – Diesel/LPG/LNG, please indicate

 

Power Supply for Control Box – 220V-240V 50Hz single phase

 

Minimum operating temperature 850 °C, please indicate

 

One year Spare Parts Package for complete maintainability

Item 18

10m Hose Pipe, indicate length

Item 19

1000 Litre Fuel Tank + Pipe System, indicate volume

Item 20

Additional chimney extension, indicate height

 

Warranty, indicate no of years

 

 

minimum technical requirements

 Mobile Incinerator

Mobile Incinerator model F

Burn Rate 100kg/h minimum

Weight (kg), please indicate:

Secondary Chamber

Gas Retention Time – 2 Seconds

Fuel – Diesel/LPG/LNG, please indicate

Power Supply for Control Box – 220V-240V 50Hz single phase

Minimum operating temperature 850 °C, please indicate

One year Spare Parts Package for complete maintainability

10m Hose Pipe, indicate length

1000 Litre Fuel Tank + Pipe System, indicate volume

Additional chimney extension, indicate height

Warranty, indicate no of years

 

 

 

minimum technical requirements

High Temperature Waste Mobile Incinerator

Item 25

HTW Mobile Incinerator model G

 

Burn Rate 100kg/h minimum

 

Weight (kg), please indicate:

 

Secondary Chamber

 

Gas Retention Time – 2 Seconds

 

Fuel – Diesel/LPG/LNG, please indicate

 

Power Supply for Control Box – 220V-240V 50Hz single phase

 

Minimum operating temperature 1200 °C, please indicate

 

One year Spare Parts Package for complete maintainability

Item 26

10m Hose Pipe, indicate length

Item 27

1000 Litre Fuel Tank + Pipe System, indicate volume

Item 28

Additional chimney extension, indicate height

 

Warranty, indicate no of years

 

 


Recent Posts

  • Incinerador con depurador húmedo tipo 1 o 3 áreas
  • Incineradores móviles de residuos en contenedores HICLOVER CA-200
  • Crematorio para perros HICLOVER A600
  • Terapia de incineración de desechos PRECIO DE QUEMA: 100-150 kg por hora HICLOVER TS150
  • HICLOVER Quemador móvil pequeño Con Rueda así como Freno
  • Cremación para perros de gran capacidad HICLOVER Versión A1500 con automóvil E-Power. Puerta
  • Planta de quemadores con controlador PLC automático con calentadores de calor duales y también HICLOVER YD-30C de doble cámara con depurador húmedo
  • Incinerador de desechos médicos HICLOVER TS10 PLC 10 kg por hora
  • Incineración de residuos HICLOVER Modelo TS75
  • incinerador de desechos médicos
  • Incinerador móvil de desechos médicos de rango pequeño con carro o rueda
  • 30kgs tasa 60kgs aceite de alimentación y también quemador de residuos minúsculo
  • Quemador tipo contenedor premontado
  • Pequeño quemador de residuos, capacidad de 10 kg por hora, control PLC Modelo TS10 (PLC).
  • Incineradores de residuos clínicos de 30 kg para residuos covid19
©2026 HICLOVER Incinerator | WordPress Theme by Superbthemes.com