The incinerator to be fully assembled wired and logic function tested in the factory, prior to dispatch.

 

–      One high flue gas temperature indicator/alarm to provide an audio/visual warning in the event of high flue gas

temperatures occurring in two stages:-

 

First stage audible alarm, second stage incinerator shutdown, with one voltage free contact for connection to a

remote alarm system.

 

–      Flexible wire control linkages to bring under fire air, overfire air and burner slide plate control to front of

incinerator.

 

–      One fire protection system, comprising fusible links over burners, deadweight fire valve, electrically

interlocked with incinerator controls.

 

–      Special feeding door with thermal lock to protect the operator from accident.

 

2.2  PRIMARY CHAMBER

 

  1. The chamber shall consists of a welded steel shell of minimum 6mm thickness plate reinforcing strips and

connections for primary air supply, start-up burner, thermal reactor, water injection and all necessary measuring probe

sockets.

 

  1. The entire chamber, including all the connections shall be lined with a composition of castable hot face

refractory suitable for a continuous service temperature of 1500 deg. C. This lining shall be separated from the steel

construction by a second layer of insulation. Heat resistant cast steel plates with many fine holes shall be lied over

the refractory lined floor of the unit with a space between the two.

 

  1. The chamber shall be externally primed and sprayed with a silicone enamel paint.

 

2.3  THERMAL REACTOR

 

  1. The reactor shall consist of welded cylindrical steel sections of minimum 9.5mm thickness plate.

 

  1. The whole chamber shall internally be constructed with a refractory lining.

 

  1. The chamber shall be provided with connection for the low temperature carbonization gas intake, the flue gas

outlet, the secondary and tertiary air supply, the reactor burner and all the required measuring probes.

 

  1. Externally the reactor shall be primed and sprayed with a silicone enamel paint.

Recent Posts

  • 30kgs tasa 60kgs aceite de alimentación y también quemador de residuos minúsculo
  • Quemador tipo contenedor premontado
  • Pequeño quemador de residuos, capacidad de 10 kg por hora, control PLC Modelo TS10 (PLC).
  • Incineradores de residuos clínicos de 30 kg para residuos covid19
  • Pequeños incineradores para los dispositivos de desechos sólidos en el patio de monitoreo de desechos
  • Tratamiento de incineración de residuos PRECIO DE QUEMA 100-150 kg por hora HICLOVER TS150
  • vigilancia de la incineración de residuos médicos
  • tratamiento y eliminación de materiales contaminados
  • Pasos de la administración de residuos médicos.
  • control de desechos médicos
  • estilo incinerador para centros de salud
  • Incineradores de basura
  • HICLOVER Waste Incinerators: Engineered for Regulatory Compliance and Decentralized Disposal
  • eliminación de residuos peligrosos
  • diagrama de bloques del quemador
©2026 HICLOVER Incinerator | WordPress Theme by Superbthemes.com