HICLOVER Incinerator

incinerators animal

Posted on April 7, 2022

Class 2          Industrial Incinerators

Class 2A:    Commercial

Incinerators for the disposal of waste that contains hazardous, possible hazardous and bio-medical waste in which the

operator exceeds 100 Kg/day.

  1. Dimensions: 2.2m(l) x 1.5m(w) x 2.5m(h)
  2. Fully automatic computer multi control system.
  3. Fuel Options- Diesel and natural gas, electricity
  4. Wasted fuel- >12L/h
  5. The incinerator should burn up to 200kg < of waste per hour.
  6. Min.temperature-750癈<
  7. Max.temperature-1000癈<

 

Course 2B:      Small Scale Incinerators for Private Use

Incinerators for the disposal of hazardous, possible hazardous and bio-medical waste in which the operator doesn’t

exceed 100 kg/ day.

 

Class 3:  General waste Incinerators

Incinerators for overall waste that is non toxic, non hazardous, non medical or does not  contain organic halogens,

i.e., selected customs, police, contraband goods, offices waste, commercial waste  and industrial wastes) in which the

operator doesn’t exceed 1 ton/ day. Parameter     Standards, Guideline, Criteria and Procedure

 

1     Fundamental Plant Design     An approved plant must have four different sections that demonstrate three principles of

Turbulence, Residence Time and Temperature are inbuilt in the plant design .The regulated sections may include but not

limited to:

 

Overall plant layout.

Feed chamber/ charging   —build by local customer

Primary Combustion Chamber. –yes

Particulate Scrubbers—- filter brick room included

Acid Gas Scrubbers—none

The stack/ chimney. –yes

two Feeding And Charging     Controlled hygienic, mechanical or automated feeding methods must be used which will

not influence the air temperature in the primary and secondary chambers of the incinerator negatively.

 

No waste is to be fed into the incinerator:

 

Please  incorporate a mechanical feeder

 

exceeded. –yes

 

3     Primary Combustion Chamber The primary combustion chamber must:

 

  1. Until the minimum temperatures have been reached.—manual feeding

judged on merits.

  1. If the minimum combustion temperatures are not maintained. –yes
  2. Whenever the previous charge has not been completely combusted in the case of batch feeding. –yes

 

  1. Until such time as the addition of more waste will not cause the design parameters of the incinerator to be

 

4     Secondary Combustion Chamber (Afterburner). The secondary combustion chamber must:

 

 

  1. Be accepted as the primary combustion zone. –yes
  2. Be equipped with a burner/s burning gas/fuel or low sulphur liquid fuels. Other combustion methods will be

judged on merits.

 

  1. Ensure primary air supply is controlled efficiently–yes
  2. Ensure minimum exit temperature is not less than 850oC—800-1000 oC

 

4     Secondary Combustion Chamber (Afterburner). The secondary combustion chamber must:

 

  1. Be accepted as secondary combustion zone. –yes
  2. Be fitted with secondary burner/s burning gas or low sulphur liquid fuel or any suitable fuel. –yes

Recent Posts

  • Incinerador con depurador húmedo tipo 1 o 3 áreas
  • Incineradores móviles de residuos en contenedores HICLOVER CA-200
  • Crematorio para perros HICLOVER A600
  • Terapia de incineración de desechos PRECIO DE QUEMA: 100-150 kg por hora HICLOVER TS150
  • HICLOVER Quemador móvil pequeño Con Rueda así como Freno
  • Cremación para perros de gran capacidad HICLOVER Versión A1500 con automóvil E-Power. Puerta
  • Planta de quemadores con controlador PLC automático con calentadores de calor duales y también HICLOVER YD-30C de doble cámara con depurador húmedo
  • Incinerador de desechos médicos HICLOVER TS10 PLC 10 kg por hora
  • Incineración de residuos HICLOVER Modelo TS75
  • incinerador de desechos médicos
  • Incinerador móvil de desechos médicos de rango pequeño con carro o rueda
  • 30kgs tasa 60kgs aceite de alimentación y también quemador de residuos minúsculo
  • Quemador tipo contenedor premontado
  • Pequeño quemador de residuos, capacidad de 10 kg por hora, control PLC Modelo TS10 (PLC).
  • Incineradores de residuos clínicos de 30 kg para residuos covid19