HICLOVER Incinerator

incinerators 300 kg per hour

Posted on April 3, 2022

Guide autoclave with vertical loading; gravity displacement type with possibility for Vacuum.

 

Capacity:      Up to 12 kg/h

 

Chamber size:      >150 Dimensions

 

Material:       Stainless steel

 

Temperature:       134 °C

 

Additional information:

 

Minimum autoclave room size shall be 150 liters and shall have a usable quantity (loading basket) of 100 liters.

Shall work based on gravity air displacement principle.

The vacuum system shall be of a thermal shock kind.

 

The pressure vessels ought to be pressure tight, the rising of the pressure (at a start pressure of below 80 mbar)

shall be lower than one mbar/min.

 

With in-build electrical heating elements for steam generation (heating elements > 4000 Kw).

Chamber and door shall be made from high quality stainless steel (e.g. AISI 3161).

Chamber in vertical position, it shall enable a simple loading/unloading of this loading basket. The baskets shall be made for the

usage of non-heat resistant waste bags, a system for the collection and controlled release of free liquids and

condensate in the waste shall be integrated.

The temperature measured at the reference measurement stage of the treatment room shall not be lower than 105°C

(TDes 0+4). The treatment time shall be ≥30 minutes at 105°C, ≥20 minutes using a temperature used of ≥121°C (TDes

0+4) and ≥10 minutes using a treatment temperature of ≥ 134.

The steering of the treatment process should be semi-automatically in addition to manual.

The Treatment Equipment shall be equipped with the following instruments:

o   treatment room temperature indicating instrument

otreatment room pressure indicating instrument

For the treatment of the outgoing air, a HEPA filter in combination with a condensation system should be used.

The filter shall be constructed in a manner that a disinfection of the filter shall be possible in an integrated condition.

 

The filters must be heat resistant, steam resistant, hydrophobic and pressure resistant for the pressure difference.

 

Cooling down phase after treatment ought to be existent; the temperature of the waste should be not higher than 80°C

after completing the cooling down process.

The pressure vessel should be equipped with a heating insulating material, the maximum outer surface temperature should be < 50°

after finishing the cooling down process.

The pressure vessel should be equipped with a heat insulation, the maximum outer surface temperature should be < 50°

Recent Posts

  • incineradores en 3 instalaciones para refinar los desechos de atención médica
  • arrojar desechos peligrosos y también incineradores de chimeneas
  • Sistema de incinerador
  • Quemadores
  • INCINERADORES LOCALES DE RESIDUOS FUERTES
  • especificación de la planta incineradora
  • Incineradores de desechos médicos
  • PROPUESTA de incinerador de desechos médicos
  • Directiva de emisiones 2000/76 / EC
  • INCINERADOR DE RESIDUOS
  • los tres incineradores para quemar y para incinerar medicamentos y compuestos nocivos
  • un incinerador de animales para la cremación de perros
  • Calentador de incineración para quemar patalogical
  • Componentes del cuerpo animal, otros desechos biomédicos, excrementos de órganos corporales
  • Incinerador capaz de manejar entre 300 y 500 kg equipado con el sistema de lavado húmedo
©2026 HICLOVER Incinerator | WordPress Theme by Superbthemes.com