SPECIFICATIONS TECHNIQUES.
Capacité destructive de 55 Kg/h jour de déchets hospitaliers  avec un p .c. i jusqu’à 3.200 Kcal/Kg
1)Type de déchet                                                                                               hospitalier
2)Pouvoir calorifique inférieur                                                                        3.200 kcal/kg
3)Humidité                                                                                                          20%
4)Teneur  en cendres et/ou inertes                                                                       8%
5)Capacité destructive nominale                                                                         55 kg/h
6)Volume chambre de combustion                                                                     1,65 m³
7)Volume chambre postcombustion                                                                   2.1 m³
8)Temps  transit des fumées en post combustion /sec.                                       <2
9)Température minimale  en postcombustion                                                     1.100° C
10)Teneur d’oxygène libre en postcombustion                                                     6%
11)Attribution refuse confectionné en sachets                                                     HDPE
12)Dispositif de chargement : hydraulique ; capacité de charge                           0.5 m³                                                     
13)Combustible prévu                                                                                           Gasoil
14)Brûleur en chambre de combustion                                                                  nbr : 1 
15)Brûleur en chambre de postcombustion                                                           nbr : 2 


•   The site is surrounded by an iron fence (sheet metal) 3 meters height from the surface of the earth in order to protect the incinerators from dust storms 
•    The iron fence must have a 5 meters Width gate 
•    Automatic anti-rust and heat electrical circuit must be provided 
•    The furnaces are highly efficient, emissions-free, safe, and environmentally friendly and have capacity of not less than 3,000 kg of materials and the rate of burning at least 400 kg / h
•    The method of feeding the furnace through a side slot or from the top and the emission of the smoke is completely prevented.
•    a furnace Must have two rooms, one of them is the  main room of not less than the “5” stoves to the process of burning materials and other secondary room of not less “2” stoves to burn resulting gas from the first process as well as the chimney
•    The main component of the body of the furnace is stainless steel box, the thickness of not less than 7 mm with a layer of zinc phosphate plated with aluminium reflector to heat
CONSTITTUTION DE L’APPAREIL.

Recent Posts

  • INCINERADOR PIROLÍTICO de residuos clínicos
  • incineradores en 3 instalaciones para refinar los desechos de atención médica
  • arrojar desechos peligrosos y también incineradores de chimeneas
  • Sistema de incinerador
  • Quemadores
  • INCINERADORES LOCALES DE RESIDUOS FUERTES
  • especificación de la planta incineradora
  • Incineradores de desechos médicos
  • PROPUESTA de incinerador de desechos médicos
  • Directiva de emisiones 2000/76 / EC
  • INCINERADOR DE RESIDUOS
  • los tres incineradores para quemar y para incinerar medicamentos y compuestos nocivos
  • un incinerador de animales para la cremación de perros
  • Calentador de incineración para quemar patalogical
  • Componentes del cuerpo animal, otros desechos biomédicos, excrementos de órganos corporales
©2026 HICLOVER Incinerator | WordPress Theme by Superbthemes.com