medical incinerator design

Posted on June 28, 2022

It is expected that the Bidder will cooperate closely with PATH and target Hospitals for the new waste handling

building/area and will make available all needed technical information, drawings, etc.,

 

The following waste streams shall be treated in the new HCW treatment center(s):

 

Infectious waste

 

Sharps waste

 

Pathological waste

 

Pharmaceutical waste including cytotoxic or genotoxic waste

 

Small amounts of chemical waste

TECHNICAL SPECIFICATION FOR PROCUREMENT OF “MEDICAL WASTE TREATMENT PLANT”

Lot-A

Specification

1.Hydroclave for Medical waste Treatment Plant: Quantity: 02 Nos.

General Requirements

The processor must be approved to sterilize  & treat the following types of medical waste:

-Liquids: Blood, body fluids etc.

-Blood bags & tubing, gloves, Gowns, drapes, etc.

-Contaminated packaging: bandage etc.

-Sharps & Sharp containers

-Disposable instruments

-Glass products

-Human and animal tissue (surgical and pathologic) –Based upon MWM regulations

-Cultures, stocks and glassware

The processor must comply with a documented efficacy level of 6log10 reduction in spore survival (99,9999%) of the

Bacillus Stearothermophilus

The processor should reduce the volume of the waste by 60% to 80% through complete dehydration and sterilization of

the waste

The  processor must have ZERO harmful emission level and meet or exceed all standards required by the EU.

The whole waste treatment system should be offered as a complete unit consisting of following equipment and

ancillaries-

(A)The sterilization processing unit

(B)Steam Boiler

(C)Tub washer

(D)Heavy duty external shredder-

(E)Conveyer belt-based on Manufacturer’s Recommendations

(F)Bin Lift/Tipper

(G)Spore tester

(A)Features and Specifications of the Sterilization Processor unit:

Technical specification of the processor:

Steam autoclave in combination with a heavy duty Fragmenting System inside the vessel/chamber

The vessel must be of Double Chamber

Capacity (kg/load) : minimum 200 kg/batch/cycle

Volume of 140-190 liters of bulk per cycle

Average Cycle time : 60 minutes

Operating temperature: 121◦C to 135◦C

Operating pressure : 1.1 Bar to 2.4 Bar

Recent Posts

  • Incineradores de pequeña gama HICLOVER Burner YDC
  • ВЫСОКОТЕХНОЛОГИЧНЫЙ ПИРОЛИТИЧЕСКИЙ ИНСИНЕРАТОР ДЛЯ МЕДИЦИНСКИХ ОТХОДОВ
  • un incinerador para nuestras clínicas dentales
  • Сжигание в крематории домашних животных
  • Мощность разрушения массой 60 кг / час
  • Suministro, entrega y también designación del sistema de incineración de desechos
  • Установки для сжигания отходов производства HICLOVER
  • Инсинератор, способный обрабатывать от 300 до 500 кг, оборудованный системой мокрого скруббера
  • instalación de fabricación establecida Calentador a diésel
  • Завод по сжиганию мусора
  • trébol medcial yz variación quemador video
  • Части тела животных , другие биомедицинские отходы , навоз органов
  • Установка для сжигания отходов HICLOVER, вид спереди
  • pequeño incinerador de residuos del centro de salud
  • печь для сжигания печей для сжигания
©2026 HICLOVER Incinerator | WordPress Theme by Superbthemes.com