Skip to content
Menu
  • Home
  • RFQ
  • Shop
  • Contact
HICLOVER Incinerator

Large Incinerator Industrial Unit – Waste Types

Posted on August 20, 2019
Large Incinerator Industrial Unit – Waste Types                         
Approx Burn Rate of 1000 KG/Hour – 18 hours/Day. Cap 7 to 9 Cbm 
Auto Continuous Feeder*
Control Panel Stand
Fuel Tank
Pollution Control & Monitoring System
Service Packs
Static Loading Mechanism*
Venturi Scrubber
Quantity 1 set
Capacity 200 kg/hr
Loading capacity 400-500kg/batch
Overall Width 8,500mm
Overall Length 10,000mm
Overall Height 3,450mm
Fuel Type Diesel
Overall Fuel Consumption
Exhaust Smokeless
Odorless
Quantity 2 sets
Capacity (200 kg/hr)/set  
Diameter 1,912mm
Height 2,962mm
Furnace Volume 5m3/Set
Furnace Exit Temperature 500-1000 deg C.
External Material Steel Plate 6t, channel
Internal Material Fire Proof, CT-160
Insulation Ceramic Wool 25T, Insulation 50T
Access Hole/Door
Burner 1 set
80,000 kcal/hr capacity
Electrica automatic ignition
Fron and Rear range of flame
ON/OFF operation
Flame detection devise
Fuel cut off devise
Diese burner
Burner Made/Type
Quantity 1 set
Diameter 900mm
Length 1500mm
External Material Stainless Steel 304-8t
Internal Material Fire Proof, CT-160
Insulation Ceramic Wool 25T, Insulation 50T
Auxiliary Door Locking Devise
Access Hole
Quantity 1 set
Diameter 1500mm
Height 2,800mm
Exit Temperature 850-1000 deg c.
External Material Stainless Steel 304-8t
Internal Material Fire Proof, CT-160
Insulation Ceramic Wool 25T, Insulation 50T
Casing Surface temperature 120 deg c.
Burner 1 set
80,000 kcal/hr capacity
Electrica automatic ignition
Fron and Rear range of flame
ON/OFF operation
Flame detection devise
Fuel cut off devise
Diese burner
Burner Made/Type
Quantity 1 set
Capacity 1000 kg/hr…Steam

Recent Posts

  • incineradores en 3 instalaciones para refinar los desechos de atención médica
  • arrojar desechos peligrosos y también incineradores de chimeneas
  • Sistema de incinerador
  • Quemadores
  • INCINERADORES LOCALES DE RESIDUOS FUERTES
  • especificación de la planta incineradora
  • Incineradores de desechos médicos
  • PROPUESTA de incinerador de desechos médicos
  • Directiva de emisiones 2000/76 / EC
  • INCINERADOR DE RESIDUOS
  • los tres incineradores para quemar y para incinerar medicamentos y compuestos nocivos
  • un incinerador de animales para la cremación de perros
  • Calentador de incineración para quemar patalogical
  • Componentes del cuerpo animal, otros desechos biomédicos, excrementos de órganos corporales
  • Incinerador capaz de manejar entre 300 y 500 kg equipado con el sistema de lavado húmedo
©2026 HICLOVER Incinerator | WordPress Theme by Superbthemes.com